HWG Sensors

Temperature  
  • Temp-1Wire: Temperature: indoor / outdoor / coolers, icebox and freezer / rack montage
  • HTemp-1Wire: Temperature + Humidity: indoor / outdoor / rack montage
  • Accuracy: ±0.5°C
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, RJ45 & terminal block 
  • Construction: Wall mount – indoor sensor
  • Accuracy: ±0.15°C
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block 
  • Construction: IP67 wall mount – external sensor

 


Converters for the Pt100 temperature sensor
 
  • Accuracy: ±0.2°C – outdoor sensor
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block 
  • Construction: Wall mount converter, temperature sensor on a 2m cable
  • Accuracy: ±0.2°C
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block 
  • Construction: Converter fits into a B type head
  • Extended temperature range: -190 .. +200°C – outdoor sensor
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block 
  • Construction: Wall mount converter, temperature sensor on a 3.5m cable

 

Humidity  
  • HTemp-1Wire: Temperature + Humidity: indoor / outdoor / rack montage
  • Accuracy: ±0.5°C temperature / ± 4% RH humidity
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, RJ45 & terminal block  
  • Construction: Wall mount – indoor sensor
  • Accuracy: ±0.4°C temperature / ± 2.5% RH humidity
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, 2 terminal blocks 
  • Construction: Wall mount – outdoor sensor
  • Note: Display with current values
Air Pressure  
  • Measurement: Air pressure, Temperature, RH humidity, Dew point
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, 2 terminal blocks 
  • Construction: Wall mount – outdoor sensor
  • Note: Display with current values
Flood/ Water Level Detector  
  • HWg-WLD Relay :WLD (Water Leak Detection) cable input. Alarm output by Relay or 1-Wire UNI bus.
Smoked and Gas Detectors  
Smoke detector (Interface: contact)  
   
Voltage and Current Sensors  
  • Sensor 0-20mA 1W-UNI : Electrically isolated current sensor for the 1Wire-UNI bus. Sensor for measuring currents in the 0–20mA or 4–20mA range. It is typically used to connect a remote industrial probe (e.g. to measure the fuel level in a tank)
  • Sensor 0-15V 1W-UNI: Electrically isolated sensor for measuring voltages from 0 to 15VDC. Typical applications include connecting external sensors (0–10V) to a monitoring system or monitoring the voltage of 12V batteries
  • Sensor 0- 60V 1W-UNI: Electrically isolated sensor for measuring voltages from 0 to 60 VDC. Typically used to monitor battery voltage in telco applications (-48V standard)
  • PowerEgg:110 to 230VAC mains voltage detector and controller with electrical isolation. Inputs and outputs are low-voltage contacts.
  • Power DETECTOR (relay contact if power connected)
  • Power CONTROL (Switch on/off power by low voltage relay contact)
  • Sens-UI: Converts electrically isolated analog voltage (0 to 15V) and current (0 to 25 mA) signals at two inputs to a RS-485 line. Fits on a DIN rail.
  • Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block
  • Construction: Converter to mount on a DIN rail
  • Sens-1W-UDI86 Multifunction Sensor: Analog and digital inputs for the 1-Wire UNI bus. Sens-1W-UDI86 features six dry contact digital inputs and eight 0-15V analog inputs. Electrically isolated, requires a 12VDC power supply.
  • 8x Voltage input, 0-15VDC
  • 6x Digital (dry contact) input
  • Output: 1-Wire UNI bus
  • Construction: Converter to mount on a DIN rail
Motion and Position Detectors