Temperature |
|
-
Temp-1Wire: Temperature: indoor / outdoor / coolers, icebox and freezer / rack montage
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-temp-1w-flat_600337_100.jpg) |
-
HTemp-1Wire: Temperature + Humidity: indoor / outdoor / rack montage
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-temp-1wire-rj11_600242_100.gif) |
-
Accuracy: ±0.5°C
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, RJ45 & terminal block
-
Construction: Wall mount – indoor sensor
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-htemp-485_box2_600343_100.jpg) |
-
Accuracy: ±0.15°C
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block
-
Construction: IP67 wall mount – external sensor
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-temp485pt100-box_600113_100.jpg) |
Converters for the Pt100 temperature sensor |
|
-
Accuracy: ±0.2°C – outdoor sensor
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block
-
Construction: Wall mount converter, temperature sensor on a 2m cable
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-temp485pt100-cable_600114_100.jpg) |
-
Accuracy: ±0.2°C
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block
-
Construction: Converter fits into a B type head
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-temp485pt100-head_600110_100.jpg) |
-
Extended temperature range: -190 .. +200°C – outdoor sensor
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block
-
Construction: Wall mount converter, temperature sensor on a 3.5m cable
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-temp-pt100-frost_600309_100.jpg) |
Humidity |
|
-
HTemp-1Wire: Temperature + Humidity: indoor / outdoor / rack montage
|
![](/sites/default/files/sites/default/ckeditor/sensor-htemp-1w_outdoor_3m_600522_100.jpg) |
-
Accuracy: ±0.5°C temperature / ± 4% RH humidity
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, RJ45 & terminal block
-
Construction: Wall mount – indoor sensor
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-htemp-485_box2_600343_100.jpg) |
-
Accuracy: ±0.4°C temperature / ± 2.5% RH humidity
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, 2 terminal blocks
-
Construction: Wall mount – outdoor sensor
-
Note: Display with current values
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-phtemp-485_t7410_600370_100_0.jpg) |
Air Pressure |
|
-
Measurement: Air pressure, Temperature, RH humidity, Dew point
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, 2 terminal blocks
-
Construction: Wall mount – outdoor sensor
-
Note: Display with current values
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-phtemp-485_t7410_600370_100_0.jpg) |
Flood/ Water Level Detector |
|
-
HWg-WLD Relay :WLD (Water Leak Detection) cable input. Alarm output by Relay or 1-Wire UNI bus.
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-hwg-wld_relay_600493_100.jpg) |
Smoked and Gas Detectors |
|
Smoke detector (Interface: contact) |
|
|
|
Voltage and Current Sensors |
|
-
30A Current probe 1W-UNI: 0–30A sensor for indirect AC current measurements: 30A Current probe 1W-UNI is a 1-Wire sensor for indirect (without cutting the wire), single-phase measurement of AC current up to 30A. The split-core current transducer can be opened in order to insert a line wire. The sensor is suitable for monitoring power consumption of racks, BTS's or server rooms.
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-30a_current_probe_1w_uni_600437_100.jpg) |
-
Sensor 0-20mA 1W-UNI : Electrically isolated current sensor for the 1Wire-UNI bus. Sensor for measuring currents in the 0–20mA or 4–20mA range. It is typically used to connect a remote industrial probe (e.g. to measure the fuel level in a tank)
|
![](/sites/default/files/sites/default/ckeditor/sensor_thumb-20ma_1w-uni_600414_100.jpg) |
-
Sensor 0-15V 1W-UNI: Electrically isolated sensor for measuring voltages from 0 to 15VDC. Typical applications include connecting external sensors (0–10V) to a monitoring system or monitoring the voltage of 12V batteries
|
![](/sites/default/files/sites/default/ckeditor/sensor_thumb-15v_1w-uni_600412_100.jpg) |
-
Sensor 0- 60V 1W-UNI: Electrically isolated sensor for measuring voltages from 0 to 60 VDC. Typically used to monitor battery voltage in telco applications (-48V standard)
|
![](/sites/default/files/sites/default/ckeditor/sensor_thumb-60v_1w-uni_600413_100.jpg) |
-
PowerEgg:110 to 230VAC mains voltage detector and controller with electrical isolation. Inputs and outputs are low-voltage contacts.
-
Power DETECTOR (relay contact if power connected)
-
Power CONTROL (Switch on/off power by low voltage relay contact)
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-poweregg_600237_100.jpg) |
-
Sens-UI: Converts electrically isolated analog voltage (0 to 15V) and current (0 to 25 mA) signals at two inputs to a RS-485 line. Fits on a DIN rail.
-
Interface: RS-485 bus (Poseidon 2250), up to 1000m, terminal block
-
Construction: Converter to mount on a DIN rail
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-sens-ui_600116_100.jpg) |
-
Sens-1W-UDI86 Multifunction Sensor: Analog and digital inputs for the 1-Wire UNI bus. Sens-1W-UDI86 features six dry contact digital inputs and eight 0-15V analog inputs. Electrically isolated, requires a 12VDC power supply.
-
8x Voltage input, 0-15VDC
-
6x Digital (dry contact) input
-
Output: 1-Wire UNI bus
-
Construction: Converter to mount on a DIN rail
|
![](/sites/default/files/sites/default/ckeditor/sensor-thumb-sens-1w-udi86_600432_100.jpg) |
Motion and Position Detectors |
|
|
|
|
|